1. Open a session in iConfig with a device you want to administer.
2. Choose the Administration tab.
3. Click the Save PROM File button.
4. The Save as PROM dialog box appears.
5. Choose a folder and then select the filename you wish to save.
NOTE
.BIN is the default extension.
6. Click the Save button to save, the file is saved.
7. Add entries to the Notes box, if desired; then click OK. If you do not
wish to enter Notes, click Close.
8. Click OK to close Succeeded dialog box. (Prom Save was successful.)
If the Management Module is removed with the SNMP Write Lock switch set
to NORMAL, all module revert to their hardware settings by default; for any
module with on-board logic, refer to its manual for details. Hardware
settings should be configured to match those made via SNMP. Always
reconfigure application modules when moving them from one chassis’ slot to
another.
Using the SNMP Write Lock Switch
1. Ensure the SNMP Write Lock switch is set to NORMAL.
2. After configuring all application module settings via SNMP, use the
iConfig application to make a backup copy of the SNMP management
board’s firmware.
3. If the SNMP Management Module needs to be replaced, set the SNMP
Write Lock switch to LOCKED.
4. Remove the old SNMP module and replace with another SNMP
module.
5. Connect to this SNMP module via iView² and then launch iConfig.
Select the Administration tab and click on List Tasks. Highlight Flashsav
and then click on the Terminate button.
6. Update the new board with the firmware backup made in Step 2.
7. Reboot the SNMP Management Module with the reboot command to
enable changes.