Remote Management (DIP Switch S1, Position 10)
This switch enables or disables the Remote Management mode. Enabling Remote
Management on the Remote module allows all SNMP configurable features for the
Remote modules to be configured from the Host module.
NOTE
The Remote Management feature must be enabled on the Remote module. The Remote
module cannot be managed by the management chassis it is located in. The local
management can read the card settings but cannot make changes to them.
By default this feature is
Disabled
. The module acts as a HOST device in this default
setting.
This feature can be selected only by setting the DIP Switches manually.
Loopback Testing
The iMcV-DS3/E3/STS-LineTerm includes two loopback test modes: Coax Loopback
and Fiber Loopback.
The following illustrations show the path that a signal takes in each of the loopback
test modes.
Each loopback performs the following: