Chapter 2:
Hardware Installation
Installing a FiberLinX Module involves the following steps:
1) Configuring the FiberLinX Module via its eight-position Dip
switch for the following:
l
Half/Full Duplex setting (data ports only),
l
designating the management traffic port,
l
host/remote or standalone operation;
2) Installation of a PowerChassis/100-Series chassis;
3) Installation of the FiberLinX Module into the above-mentioned
PowerChassis; and,
4) Selecting a crossover or pass-through connection for the twisted
pair data port.
Configuring FiberLinX Modules
FiberLinX Modules have an eight-position Dip switch, located at position
S2 (shown below), for configuring the module.
Figure 2.1 Dip Switch Location on FiberLinX
(default settings shown)
2.1